Classification: | Imaging Diagnostic Equipment |
---|---|
Type: | Digital Imaging System |
Certification: | CE, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item |
Model |
Quantity |
Brand |
Console |
KZT70 |
1pc |
Self-produced |
Generator |
FSQ65 |
1pc |
Self-produced |
X-ray tuble assembly |
E7254FX |
1pc |
Canon |
Collimator |
XSQ40 |
1pc |
Self-produced |
Diagnostic Table |
ZDC40 |
1pc |
Self-produced |
Gird
|
1.0/1.8m
|
2pc
|
JPI
|
Ionization chamber
|
SSMC601
|
1pc
|
Clermond
|
Flat panel detector |
DRF-1717RF |
1pc |
Self-produced |
Digital workstation |
DRA80 |
1set |
Self-produced |
Item
|
Content
|
Technical Parameters
|
Power supply |
Voltage
|
380V±38V
|
|
Frequency
|
50Hz±1Hz
|
|
Capacity
|
≥105kVA
|
|
Internal resistance
|
≤0.11Ω
|
Generator |
Output power
|
65kW
|
|
Inverter frequency
|
440kHz
|
|
Tube voltage
|
40kV~150kV
|
|
Tube current
|
10mA~800mA
|
|
Exposure time
|
1ms~10000ms
|
|
MAS
|
0.1~1000 mAs
|
|
Perspective tube voltage
|
40kV~125kV continuous adjust
|
|
Perspective tube current |
0.5mA~10mA (continuous fluoroscopy)
5mA~20mA (pulse fluoroscopy) |
X-ray tuble assembly |
Output Power
|
Big focus 102kW Small focus 40kW
|
|
Anode capacity
|
285KJ(400kHU)
|
|
Component capacity
|
950kJ(1339kHU)
|
|
Rotating anode speed
|
9700rpm(180 Hz)
|
|
Tube focus
|
1.2mm /0.6mm
|
|
Target angle
|
12°
|
|
X-ray coverage
|
430 × 430 mm (SID =1000 mm )
|
|
Intrinsic filtration
|
1.1 mm Al / 75 kV
|
Multi-function diagnostic table |
Table tilting range
|
+90°~ -15°
|
|
Point device longitudinal movement
|
970mm
|
|
Table surface lateral movement range
|
250mm
|
|
Table panel load bearing
|
135kg
|
|
SID
|
1100mm1800mm
|
|
Tube stand swing range
|
+45°~ -45°
|
|
Tube rotation
|
+180°~ 0°(Optional)
|
|
Fixed grid ( ACS ) |
Grid density 80L/cm
|
|
|
Grid ratio 12:1
|
|
|
Focus distance 100cm180cmdual grid electric switching
|
|
|
Size 18inch x 18inch
|
Dynamic flat panel detector DRF-1717RF |
Effective area
|
434mm(H)×434mm(V)
|
|
Phase matrix
|
2816(H)×2816(V)
|
|
Phase spacing
|
154μm
|
|
Pulse fluoroscopy |
12 fps / 1408 x 1408
16 fps / 1024 x 1024 22 fps / 768 x 768 |
|
Continuous fluoroscopy |
13fps/1048x1048
20 fps / 1024 x 1024 30 fps / 768 x 768 |
|
Spatial resolution
|
Min. 3.7Lp /mm
|
|
A / D conversion
|
16bit
|
|
Energy range
|
40 ~ 150 kVp
|
|
Operating mode
|
8kinds
|
|
Image output and control
|
Image data: 16-bit LVDS/command control: Ethernet (1000BASE - T)
|
Digital X-ray photography / perspective operating system DRA80
|
Basic operation
|
Create patients' information, create emergency patients, create new exams, and query.
|
|
Additional operation
|
Open inspection, protection check items, delete check items in the local interface, send check, print check, output image, point
mode parameters |
|
|
select focus size, perspective mode parameter configuration, select patient shape, check bulb heat capacity, storage mode,
exposure mode selection, add body mark to image, zoom in and out, drag image, image crop, image polarity Turn, adjust symphony processing parameters, rotate or flip images, window width window level control, save images, delete images, heavy Set image, mode settings, playback perspective image. |
|
Image observation
|
View layout, view images DICOM information, set cursors to arrows, snapshots, image scaling and drag and drop, reset, image
rotation and flip, image reverse, measurement, advanced printing. |
|
System Management
|
Edit user, create user, delete user, task
List management, detector correction |