• Scientific Equipment Digital Display Oscillation Incubator
  • Scientific Equipment Digital Display Oscillation Incubator
  • Scientific Equipment Digital Display Oscillation Incubator
  • Scientific Equipment Digital Display Oscillation Incubator
  • Scientific Equipment Digital Display Oscillation Incubator

Scientific Equipment Digital Display Oscillation Incubator

After-sales Service: on-Line After Sale Service
Warranty: on-Line After Sale Service
Application: Hospital, Lab
Customized: Customized
Certification: CE
Structure: Vertical
Gold Member Since 2024

Suppliers with verified business licenses

Jiangsu, China

Basic Info.

Model NO.
YHZHP-150G
Material
Steel
Type
Incubator
Temperature Control Range (ºC)
5-50
Volume (L)
150
Heating Power (W)
100
Refrigeration Power (W)
128
Outside Size (Cm)
60X56X155
Transport Package
in Carton
Specification
60× 56× 155cm
Trademark
Longcare
Origin
China
Production Capacity
100 Pieces

Product Description

 It has function of cooling and heating two-way adjusting temperature. It is the necessary instrument in plant,biology microbiology,hereditary virus,medical science,environment-protecting,farming,forestry, animal husbandry and so on.

Main features. 

1. The heat insulation material of the box body is polyurethane foam plastic foamed on site, which has strong anti-interference ability to external heat (cold) sources.
2. The inner cavity is made of engineering plastic molding technology, which has strong corrosion resistance.
3. All-glass door is convenient for observing the working cavity.
4. In order to protect the refrigeration compressor, the control circuit is designed with power-off protection and 4-minute delay function. 5, automatic temperature control, using red LFD display to display numbers.

Matters needing attention in safe operation of biochemical incubator Biochemical incubator is one of the commonly used equipment in the laboratory. Scientific maintenance and safe operation can greatly improve the service life of biochemical incubator. The following points should be paid attention to in the maintenance and safe operation of biochemical incubator:
1 The biochemical incubator should be installed in a place where the temperature and humidity change little as possible, using a three-pin plug? The socket should be properly grounded.
2 Before starting the biochemical incubator, you should be fully familiar with and understand the instructions of the supporting instruments and meters, and master the correct use methods.
It is forbidden to contain volatile chemical solvents? Explosive gas and flammable gas are placed in the box, and flammable spray should not be used near the incubator? To avoid spark ignition.
4 always check whether there is air leakage in the gas path.
5. The biochemical incubator has power-off protection function, so it takes about one and a half minutes for the compressor to start again after stopping, so as to better protect the compressor.
6 The distance between the condenser and the wall of the biochemical incubator should be greater than 100mm, the side of the box should have a gap of 50mm, and the top of the box should have at least 300mm space to ensure good heat dissipation.
7 When handling, repairing and maintaining the biochemical incubator, collision and shaking should be avoided, and the maximum inclination should be less than 45 degrees.
8 When stopping using for a long time, turn off the main power supply and the power switch at the back of the equipment.  At the same time, the biochemical incubator should avoid opening the door frequently to keep the temperature stable and prevent dust and dirt from entering the studio.
9 The inside and outside of the box should be kept clean every day, and should be cleaned after each use. If you don't use it for a long time, you should always wipe the tank wall and the surface of the equipment to keep it clean and increase the transparency of the glass. Do not use acid, alkali or other corrosive solutions to wipe the external surface.
10 Turn off the power switch after the culture. If you don't take out the experimental samples immediately, please don't open the door.
11 The biochemical incubator should not be used in abnormal environments such as high voltage, high current and strong magnetic field, and it should be implemented in strict accordance with the electrical safety operation rules.

 
 TypeNo. Temperature Contrd Range (ºC) Volume (L) Heating Power (W) Refrigeration Power (W) Outside Size (cm)
YHZHP-150G 5-50 150 100 128 60X56X155
 
 