Classification: | Imaging Diagnostic Equipment |
---|---|
Type: | X Ray Equipment |
Group: | Middle-aged and Old |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item
|
Content
|
Technical parameter
|
|
|
Power supply
|
Voltage
|
380V±38V
|
|
|
|
Frequency
|
50Hz±1Hz
|
|
|
|
Capacity
|
≥105kVA
|
|
|
|
internal resistor
|
≤0.17Ω
|
|
|
High voltage generator
|
Photography
|
Power Output
|
71kW
|
|
|
|
Inverter Frequency
|
440kHz
|
|
|
|
Tube Voltage
|
40kV-150kV step regulation
|
|
|
|
Tube Current
|
10mA-800mA step regulation
|
|
|
|
Exposure time
|
1ms-10000ms step regulation
|
|
|
|
mAs
|
0.1-900mAs
|
|
|
Fluoroscopy
|
Tube Voltage
|
40kV-125kVcontinuous regulation
|
|
|
|
Tube Current
|
0.5mA-10mA Continuous regulation
|
|
|
|
|
5mA-20mA Pulse fluoroscopy
|
|
X-ray tube assembly
|
|
Tube Brand
|
Canon
|
|
|
|
Focus: Large Focus/Small Focus
|
1.2mm /0.6mm
|
|
|
|
Input Power
|
Large focus: 75kW small focus: 27kW
|
|
|
|
Anode angle
|
12°
|
|
|
|
Anode heat capacity
|
210kJ (300kHu)
|
|
|
|
Thermal capacity
|
900 kJ (1250KHU)
|
|
|
|
Rotary anode speed
|
9700rpm
|
|
Collimator
|
|
Collimator field of view light
|
Halogen lamp, AC24V/100W
|
|
|
|
Visible light illumination
|
Average illumination brightness: >100Lux
|
|
|
|
Light field exposure time
|
5-45s, 5s per step
|
|
Micro-computer control remote diagnostic table
|
|
Material of the tabletop
|
high strengthlow absorb carbon fiber
|
|
|
|
Rotation of the table
|
+90°~0°~-25°
|
|
|
|
Transverse travel of table
|
±110mm
|
|
|
|
Longitudinal travel of the photography holder and film spot device
|
≥720mm
|
|
|
|
X-ray Focus-film gauge
|
1100 mm-1500 mm, adjustable by hand
|
|
|
|
Table panel equivalent filtration
|
≤1.2mmAl
|
|
|
|
Table height from the ground
|
900mm
|
|
|
|
Table surface size
|
2100mm×796mm
|
|
|
|
Rotating foot plate
|
±360° rotation
|
|
|
|
Minimum distance from the compressor to table surface
|
≤150mm
|
|
|
|
Compressor force
|
80N-130N
|
|
|
|
Foot panel
|
±360° rotatable
|
|
|
|
Fixed grid for table
|
Grid density: 103L/INCH, Grid ratio: 10:1,focusing distance: 130cm, fixed type: 15″×18″
|
|
Fixed grid for table
|
Grid density: 103L/INCH, Grid ratio: 10:1,focusing distance: 130cm, fixed type: 15″×18″
|
|
Brand
|
Canon
|
Imaging Intensifier
|
Field of view size
|
230mm
|
|
Resolution
|
52 Lp/cm
|
|
Brand
|
Germany BASLER
|
CCD camera
|
Signal to noise ratio
|
45 dB
|
|
Cell size
|
5.86×5.86μm
|
|
Number of valid pixels
|
1920×1200 spot film
|
Flat Panel Detector
|
Material
|
CsI
|
|
Image Sensor
|
Amorphous silicon thin film transistor
|
|
Pixel size
|
154μm
|
|
Effective pixel size
|
2816H*2816V
|
|
Effective area(H x V)
|
434H*434V
|
|
Image transmission
|
Gigabit Ethernet
|
|
Gray scale
|
16bit
|
|
Spatial resolution
|
3.25 Lp/mmCsI
|
|
Energy range
|
40kV -150kVP
|
|
Power input
|
DC24V
|
Digital Imaging Acquisition System
|
Computer system
|
Computer: B150 PLUS motherboard; Processor: Intel Core, I5 6400
Memory: 8 GB DDR3 Hard disk: 1T SATA (7200 rpm) Optical drive: DVR-221CHV CD burner NIC: Intel(R)gigabit CT Graphics card: gtx1050 |
|
Display
|
DELL U2412Mc display
|
|
Software function |
1. Basic functions: register new patient information; start new check; anonymous registration; WorkList search and advanced
search; WorkList refresh; WorkList information import; check list; view image; film print 2. The acquisition part is divided into gastrointestinal acquisition and DR acquisition functions: * Gastrointestinal acquisition function: bed selection; patient shape selection; specific examination protocol selection; gastrointestinal and contrast protocol selection; selected protocol list; real-time image noise reduction selection; real-time image enhancement selection; single frame storage; continuous perspective storage; Frame exposure storage; sequence exposure storage; real-time image horizontal flipping; real-time image vertical flipping; generator perspective state switching; perspective time accumulation; fluoroscopy time clearing; ABS function switch; fluoroscopy dose energy efficiency. *DR acquisition function: window width window position adjustment; 90° rotation to the left; 90° rotation to the right; horizontal mirroring; vertical mirroring; image negative; cropping frame; exposure parameter setting; stadium focus switching; exposure mode selection; ionization chamber selection ; exposure actual dose value; system status indicator. 3. Image viewing function: image zooming; partial zooming; original size; recovery window size; image grid display; 90° left rotation; 90° rotation to the right; horizontal mirroring; vertical mirroring; text logo; line logo; angle logo; Marking; cropping frame; rectangle marking; circle marking; polygon marking; length correction; four-corner information display; ruler display; window width window level adjustment; sequence image playback; image output; silhouette function; deleting image; image enhancement; ; image negative. 4.Film printing function: add image; insert image; delete image; clear image; image layout; image selection; print format; film print setting; film format setting; add, modify, delete printer settings. 5. Report editing function: open report; save report; export report; add report; delete report; print preview; printer setting; report template editing; image list; add report template; delete case template. 6.Service function: Daily settings: system settings; check protocol editing; system log settings; load user configuration. Advanced settings: restart the system; IR settings; IR correction; search for questions; hardware settings; backup recovery; language settings. |